135 selected designs · One 12-hour lab test at 37°C · 2026
Eight had no cutting measurement: their proteins were the wrong size or would not dissolve.
Scientists designed enzymes to act as molecular scissors. In a 12-hour lab test, 78 of 135 designs cut no more than 10% of the target material; 49 cut more.
Eight produced protein of the wrong size or protein that would not dissolve. They have no cutting measurement. A small amount of cutting is still activity: 10% is not a universal pass mark. This selected batch does not show how useful the enzymes would be in practice.
More Detail, Sources and Data
49 of 135 selected enzyme designs (36.3%) crossed the study's cutoff: cutting more than 10% of the target material in a 12-hour laboratory test. Another 78 cut no more than 10%; four produced the wrong-size protein and four would not dissolve. In the chart, ‘cis’ means the enzyme and target are attached. ‘Cleavage’ means cutting, ‘insoluble’ means unable to dissolve, and ‘non-numeric’ means no cutting measurement, not zero cutting.
The laboratory is a different filter
The researchers designed enzymes intended to cut a protein target. In this screen, the enzyme and its target were attached to each other. After 12 hours at 37°C, the team measured how much cutting had occurred, correcting for the background signal without zinc.
The chart follows all 135 designs selected and ordered for that laboratory screen. It does not show every candidate generated on a computer. Earlier computational filters had already removed designs, and the supplementary methods say the discarded sequences were not retained.
A cutoff is not a verdict on every design
A design below 10% is not necessarily inactive. The threshold separates measured amounts of cutting; it does not turn a continuous result into a universal pass or fail. Protein concentrations were not standardized across the screen.
The two design groups also went through different selection procedures. Their combined outcome is a useful account of this selected screen, not a general AI success rate, a controlled comparison of two methods or evidence of a medical treatment.
The useful question is not just how many promising designs emerged. It is what happened to the whole selected batch when it reached the laboratory.
Sources, Method & Data
The total is 135 designs selected and ordered for testing, listed in Supplementary Table S3. Cutting was measured for 127 of them. The strict threshold is greater than 0.10, using unrounded original values. ZnO4 is printed as 0.10 in the supplementary table but recalculates to 0.1026764266, so it belongs above the cutoff. This test did not measure health effects or cutting a separate target molecule; the enzyme and its target were attached.
| Screen outcome | Designs | Share of 135 |
|---|---|---|
| Cut more than 10% | 49 | 36.3% |
| Cut 10% or less | 78 | 57.8% |
| Wrong-size protein | 4 | 3.0% |
| Protein would not dissolve | 4 | 3.0% |
Rounded percentages sum to 100.1%. Counts sum to 135. Original data: Chen et al., Zenodo record 22654831, CC BY 4.0. This is a new Vastkind visualization and recalculation, not a reproduction of a publisher figure. The software archive's MIT license is distinct from the dataset license.
Nature paper · Supplementary methods and Table S3. Public abstract, figure caption, complete supplementary methods and original numerical data checked; subscription main text not claimed as independently read.